  • VE4001S2T2B6
    VE4001S2T2B6 | DeltaV™ 32-Channel Discrete Input Terminal Block
    Manufacturer: Delta V Product Number: VE4001S2T2B6 Product type: Standard I/O Termination Block Operating temperature: -40 to 70℃(-40 to 158℉) Storage Temperature: -40 to 85℃(-40 to 185℉) Relative humidity: 5 to 95%, non-condensing Airborne contaminants: ISA-S71. 04-1985 Airborne Contaminants Class G3 Conformal coating Protection rating: IP20 Discrete Input Card: 8 Channels, 24V DC, Dry Contact Dimensions(H*W*D,approx): 10.7cm*4.1cm*10.5cm
  • SE4305T01
    Emerson DeltaV SE4305T01 IS DI NAMUR CHARM Communications Adapter Detection
    A DeltaV SE4305T01 IS DI NAMUR CHARM Communications Adapter with model number SE4305T01 has been detected. It is described by Emerson as an IS (intrinsically safe) Digital Input Characterization Module (CHARM) designed for NAMUR sensors.
  • ILM0703P01A0000
    Schneider ILM0703P01A0000 Frensiz Entegre Servo Motor
    Complementary [Us] Rated Supply Voltage 250...700 V Continuous Stall Current 3 A Continuous Stall Torque 19.47 lbf.in (2.2 N.m) Peak Stall Torque 77.00 lbf.in (8.7 N.m) Nominal Output Power 720 W Nominal Torque 10.18 lbf.in (1.15 N.m) Nominal Speed 6000 rpm Maximum Current Irms 12 A Line Rated Current 1.5 A
  • ASIABLB3002 -Kerien
    ASIABLB3002
    Range Of Product Phaseo AS-Interface Product Or Component Type Power supply Power Supply Type Regulated switch mode Output Voltage 30 V DC AS-Interface line Kw Rating 72 W Input Voltage 100...240 V AC phase to phase L1-L2 100...240 V AC single phase N-L1 Power Supply Output Current 2.4 A Operating Position Vertical Complementary Input Voltage Limits 85...264 V Network Frequency Limits 47…63 Hz Input Voltage Tolerance - 15...10 % Inrush Current 30 A Cos Phi 0.65 Efficiency 83 % 30 V Power Dissipation In W 14.7 W 30 V Current Consumption 0.5 A Input Protection Type Integrated fuse (not interchangeable) Line And Load Regulation 3 % Residual Ripple 300 mV Holding Time >= 10 ms Output Protection Type Against overload 1.1 x In Against overvoltage tripping if U > 1.2 x Un Against short-circuits automatic reset Against undervoltage tripping if U < 0.95 x Un
  • 142U3A200CACAA165240 -Kerien
    142U3A200CACAA165240
    The Emerson Nidco servo motor 142U3A200CACAA165240 allows you to control speed with very accurate position accuracy and convert voltage signals into torque and speed to drive control objects. Servo motor rotor speed is controlled by the input signal, and can react quickly, in the automatic control system, used as an executive component, and has the characteristics of small electromechanical time constant, high linearity, starting voltage, etc., can convert the received electrical signal into the angular displacement or angular speed output on the motor shaft.
  • ATV1200 5.906.028 -Kerien
    ATV1200 5.906.028
    Power unit ATV1200C-5.906.028 Inverter Power module PLC Power unit
  • BMXNOE0100
    network module, Modicon M340, Modbus/TCP, 1 x RJ45, flash memory card
    M340 serves as a all-in-one CPU Plug-and-work solution Reduced startup time Increased network reliability and maintainability Reduced total cost of ownership Environmental performance of the product
  • LV847283 -Kerien
    LV847283
    Micrologic 5.0 X control unit, for Masterpact MTZ circuit breakers, fixed, LSI protections
  • 6DD1606-0AD0 -Kerien
    6DD1606-0AD0
    Siemens Drive T400 Technology Module 6dd1606-0ad0 SIMADYN D MIXED INPUT/OUTPUT MODULE EM11T GENERATOR/TURBINE CONTROL
  • TCSESM163F23F0 -Kerien
    TCSESM163F23F0
    This switch is part of the Modicon Networking range, an offer of industrial network switches. This TCP/IP extended managed switch has 10/100BASE-TX - 16 ports for copper cable. Ethernet services are configured via web server, VLAN, multicast filtering, data stream control, IGMP snooping, SNMP traps and SYSLOG. It is a network switch with a supply voltage of 12V to 48V, a power consumption of 9.4W and maximum number of switches in a ring is 50. It is furnished with 6-way removable connector. The supported transmission medium is twisted shielded pair CAT 5E copper cable. It is an IP20 rated product. Its dimensions are 111mm (width) x 111mm (depth) x 131mm (height). It weighs 0.6kg. It is suitable for all industrial automation segment applications. This switch is part of the Modicon Networking range, an offer of industrial network switches. This TCP/IP extended managed switch has 10/100BASE-TX - 16 ports for copper cable. Ethernet services are configured via web server, VLAN, multicast filtering, data stream control, IGMP snooping, SNMP traps and SYSLOG. It is a network switch with a supply voltage of 12V to 48V, a power consumption of 9.4W and maximum number of switches in a ring is 50. It is furnished with 6-way removable connector. The supported transmission medium is twisted shielded pair CAT 5E copper cable. It is an IP20 rated product.
  • 9662-810
    Triconex 9662-810 Panel Field Termination Option
    Triconex 9662-810 Panel Field Termination Option, 4.5 in (11.43 cm) Width (across DIN rail), 5 in (12.7 cm) Length (along DIN rail) and 4.25 in (10.795 cm) Height (out from DIN rail)  --Automatic on-load voltage regulation for single transformers --Automatic on-load voltage regulation for 4 to 8 transformers in parallel operation, based on the minimum loop current principle or the master-slave follower pinciple  --Control of up to 30 switchgears --Interlocking modules for different wiring methods, ready to use --Various reservation processing functions --Synchronization, simultaneous detection and voltage detection --Dual-position universal switch --32-position selector switch
  • HCU3700/3703E
    TRICONEX HCU3700/3703E Isolated Analog Input
    Analog Input Modules Analog Input (AI) Modules includes three independent input channels. Each input channel receives variable voltage signals from each point, converts them to digital values, and transmits the values to the three Main Processor modules on demand. In TMR mode, one value is then selected using a midvalue selection algorithm to ensure correct data for every scan. Sensing of each input point is performed in a manner that prevents a single failure on one channel. Analog Input Modules require a separate external termination panel (ETP) with a cable interface to the Tricon backplane. Each module is mechanically keyed for proper installation in a Tricon chassis. affecting another channel. Each Analog Input Module sustains complete, ongoing diagnostics for each channel. Failure of any diagnostic on any channel activates the Fault indicator for the module, which in turn activates the chassis alarm signal. The module’s Fault indicator merely reports a channelfault, not a module failure—the module can operate properly with as many as two faulty channels.
  • HCU3700/3703E
    TRICONEX HCU3700/3703E Isolated Analog Input
    Analog Input Modules Analog Input (AI) Modules includes three independent input channels. Each input channel receives variable voltage signals from each point, converts them to digital values, and transmits the values to the three Main Processor modules on demand. In TMR mode, one value is then selected using a midvalue selection algorithm to ensure correct data for every scan. Sensing of each input point is performed in a manner that prevents a single failure on one channel. Analog Input Modules require a separate external termination panel (ETP) with a cable interface to the Tricon backplane. Each module is mechanically keyed for proper installation in a Tricon chassis. affecting another channel. Each Analog Input Module sustains complete, ongoing diagnostics for each channel. Failure of any diagnostic on any channel activates the Fault indicator for the module, which in turn activates the chassis alarm signal. The module’s Fault indicator merely reports a channelfault, not a module failure—the module can operate properly with as many as two faulty channels.
    Tags : Invensys
  • LV525342
    LV525342 circuit breaker
    LV525342 circuit breaker EasyPact CVS250F, 36 kA at 415 VAC, 200 A rating thermal magnetic TM-D trip unit, 4P 3d EasyPact CVS250F is a 4 poles 3d fixed circuit breaker with a high level of performance and cost-saving functionality. It is an optimal choice for small and medium-sized buildings protection applications. The breaking capacity (Icu) is 36kA rms at 415VAC 50/60Hz. The operational voltage is 440VAC 50/60Hz. This product embeds a 200A rating thermal-magnetic trip unit (TMD). TMD trip unit provides an adjustable thermal overload protection and a fixed magnetic protection. This 4 poles version (140mm x 161mm x 86mm) comes with a variety of optional functions and accessories. EasyPact CVS250F is compliant with international standards (IEC 60947, CCC, EAC). It can be installed in class II insulation switchboards as it is a class II front face device (IEC 60664-1).
  • VW3A3202
    extended Input Output card, Altivar VW3A3202
    This extended I/O card enables your drive to meet the needs of more complex or extensive applications. It comprises four logic inputs, two analog inputs, one input for PTC probe and one frequency control input. It also comprises three logic outputs and two analog outputs. It is compatible with Altivar 61 and Altivar 71.