  • 9662-810
    Triconex 9662-810 Panel Field Termination Option
    Triconex 9662-810 Panel Field Termination Option, 4.5 in (11.43 cm) Width (across DIN rail), 5 in (12.7 cm) Length (along DIN rail) and 4.25 in (10.795 cm) Height (out from DIN rail)  --Automatic on-load voltage regulation for single transformers --Automatic on-load voltage regulation for 4 to 8 transformers in parallel operation, based on the minimum loop current principle or the master-slave follower pinciple  --Control of up to 30 switchgears --Interlocking modules for different wiring methods, ready to use --Various reservation processing functions --Synchronization, simultaneous detection and voltage detection --Dual-position universal switch --32-position selector switch
  • HCU3700/3703E
    TRICONEX HCU3700/3703E Isolated Analog Input
    Analog Input Modules Analog Input (AI) Modules includes three independent input channels. Each input channel receives variable voltage signals from each point, converts them to digital values, and transmits the values to the three Main Processor modules on demand. In TMR mode, one value is then selected using a midvalue selection algorithm to ensure correct data for every scan. Sensing of each input point is performed in a manner that prevents a single failure on one channel. Analog Input Modules require a separate external termination panel (ETP) with a cable interface to the Tricon backplane. Each module is mechanically keyed for proper installation in a Tricon chassis. affecting another channel. Each Analog Input Module sustains complete, ongoing diagnostics for each channel. Failure of any diagnostic on any channel activates the Fault indicator for the module, which in turn activates the chassis alarm signal. The module’s Fault indicator merely reports a channelfault, not a module failure—the module can operate properly with as many as two faulty channels.
  • HCU3700/3703E
    TRICONEX HCU3700/3703E Isolated Analog Input
    Analog Input Modules Analog Input (AI) Modules includes three independent input channels. Each input channel receives variable voltage signals from each point, converts them to digital values, and transmits the values to the three Main Processor modules on demand. In TMR mode, one value is then selected using a midvalue selection algorithm to ensure correct data for every scan. Sensing of each input point is performed in a manner that prevents a single failure on one channel. Analog Input Modules require a separate external termination panel (ETP) with a cable interface to the Tricon backplane. Each module is mechanically keyed for proper installation in a Tricon chassis. affecting another channel. Each Analog Input Module sustains complete, ongoing diagnostics for each channel. Failure of any diagnostic on any channel activates the Fault indicator for the module, which in turn activates the chassis alarm signal. The module’s Fault indicator merely reports a channelfault, not a module failure—the module can operate properly with as many as two faulty channels.
    Tags : Invensys
  • 9863-710 Analog Output Panel
    Triconex Tricon Invensys 9863-710 Analog Output Panel
    Introduce for Triconex Tricon's control system: The main features of Tricon's control system Tricon is a programmable and process control technology with high fault tolerance. Its characteristics are as follows: A. Triple modular redundancy structure (TMR) is provided, with three identical sub-circuits each performing an independent degree of control. There is also a dedicated hardware/software architecture for "voting" on input and output. Ability to tolerate harsh industrial environment. C. It can be installed on site and can be installed and repaired at the module level online on site without disturbing the field wiring. D. Supports up to 118 I/O modules (analog and digital) and optional communication modules. Communication modules can Connect to Modbus hosts and dependents, or to Foxboro and Honeywell Distributed Control System (DCS), other Tricons in a peer-to-peer network, and external hosts on a TCP/IP network. E. Can support remote I/O modules located up to 12 km away from the mainframe. F. Develop and debug the control program by using the programming software based on Windows NT system. G. Intelligent functions in input and output modules to reduce workload on the main processor. Each I/O module has three microprocessors. The input module's microprocessor filters and repairs the input and diagnoses hardware failures on the module. The output module microprocessor provides information for the voting of the output data, checks the validity of the output state through the feedback loop voltage at the output end, and can diagnose the field line problems. H. Provide comprehensive online diagnosis with repair capability. I. Routine maintenance can be performed while Tricon is up and running without interrupting the control process. J. Provide "hot standby" support for I/O modules, which can be used in certain critical situations where services cannot be provided in a timely manner.
  • 9761-210
    Triconex 9761-210 Panel Field Termination Option
    Triconex 9761-210 Panel Field Termination Option, 4.5 in (11.43 cm) Width (across DIN rail), 5 in (12.7 cm) Length (along DIN rail) and 4.25 in (10.795 cm) Height (out from DIN rail) Simple Type: Termination Panel
    A total of