Analog Input (AI) Modules includes three independent input channels. Each input channel receives variable voltage signals from each point, converts them to digital values, and transmits the values to the three Main Processor modules on demand. In TMR mode, one value is then selected using a midvalue selection algorithm to ensure correct data for every scan. Sensing of each input point is performed in a manner that prevents a single failure on one channel.

Analog Input Modules require a separate external termination panel (ETP) with a cable interface to the Tricon backplane. Each module is mechanically keyed for proper installation in a Tricon chassis. affecting another channel. Each Analog Input Module sustains complete, ongoing diagnostics for each channel.

Failure of any diagnostic on any channel activates the Fault indicator for the module, which in turn activates the chassis alarm signal. The module’s Fault indicator merely reports a channelfault, not a module failure—the module can operate properly with as many as two faulty channels.

  • Item NO.:

    HCU3700/3703E
  • Payment:

    T/T
  • Product Origin:

    France
  • Shipping Port:

    Xiamen
  • Lead Time:

    1 week
  • Order(MOQ):

    1
  • Product weight:

    460
  • Product Detail

Contact


Eugene --Sales Manager

E-mail:eugene@kerienplc.com

Tel.& WeChat:86-13606038172

QQ:1906683268

Add: 1803 B-Building Taidi Haicang, Xiamen, China


Product Packing

· Original package or international import package.

Shipping and delivery

· Items will be shipped within 3 business days from payment confirmation

via UPS DHL FEDEX TNT or EMS etc

· We can always deliver in prompt

Payment Terms

· Buyer Pays the shipping Charge and handling worldwide.

· We accept TT.

 

ABOUT US 

Kerien Automation Co., Ltd. is located in the beautiful coastal city - Xiamen. It is a high-tech enterprise specializing in large-scale system spare parts (distributed control system, programmable controller, redundant fault-tolerant control system, robot control system, large servo control system) and other imported automation system spare parts, module sales and system integration. The automation brand products have a strong advantage, the company is equipped with professional technical personnel, aiming to provide customers with better service.
Dade Huicheng Technology (Xiamen) Co., Ltd. which is in the spirit of professionalism, integrity, and cooperation,  dedicated to provide customers with better service, better price. Welcome to inquire.

 

Advantage Products

TRICONEX EICM2 EICM 4118 7400145-100 REV. B 3
TRICONEX ENHANCED MAIN PROCESSOR II BOARD MP 3008 REV: B5
TRICONEX Expansion Chassis 7400027-100
TRICONEX Expansion Chassis 7400028-100
TRICONEX Expansion Chassis High Density 8111
TRICONEX FSDO 7400159-030 rev. B8
TRICONEX History & Statistic Kit 9000011-000
TRICONEX ICM4101 USPP ICM4101
TRICONEX Input Digital Module Assy 2553-300
TRICONEX Input Digital Module Assy 3501E
TRICONEX Interface Module 5 Cable 7400078-100 EICM4107 . 4889
TRICONEX Main Chassis 3000604-100
TRICONEX Main Chassis High Density 8110
TRICONEX Main Processor 3006 EMPII
TRICONEX Model 2500-2 Clean used unit
TRICONEX Model 2600-2 Clean used unit
TRICONEX Model 3501 Clean used unit
TRICONEX Model 3601 Clean used unit
TRICONEX Model 4500 Highway Interface Clean used unit
TRICONEX Module Supervised DO Assy 3614E
TRICONEX NCM4320 USPP NCM4320
TRICONEX Outpout Module 3708E
TRICONEX Output Module Digital Assy 2553-300
TRICONEX Output Module Digital Assy 2651
TRICONEX Output Module Digital Assy 2651-100
TRICONEX Output Module Digital Assy 2652-300
TRICONEX Output Module Digital Assy 2652-310
TRICONEX Output Module Digital Assy 2652-350
TRICONEX Output Module Digital Assy 2652-350
TRICONEX Output Module Digital Assy 2750
TRICONEX Output Module Digital Assy 2755-020
TRICONEX Output Module Digital Assy 2755-020
TRICONEX Output Module Digital Assy 3601E
TRICONEX Output Module Digital Assy 3604E
TRICONEX Output Module Digital Assy 3624
TRICONEX Output Module Digital Assy EICM 4107
TRICONEX Power Module 8300
TRICONEX Power Module 8300A
TRICONEX Power Module 8305
TRICONEX Power Module 8305A
TRICONEX Power Module 8310
TRICONEX Processor Model 3002 Clean Used Unit
TRICONEX Processor Module Assy 3003 EMPII
TRICONEX Rack and Power Supply 
TRICONEX Relay Outpout for 2658 74000110-010
TRICONEX Remote Extender Module Assy 4200 RXM
TRICONEX Safety Manager Module 4409 SMM

Our service

1)100% New - Original Factory Seal 
2)Warranty: 12 months
3)Package: Original packing with cartons
4)Delivery time: Shipped in 3 days after payment

Leave A Message

If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

Related Products
9662-810
Triconex 9662-810 Panel Field Termination Option

Triconex 9662-810 Panel Field Termination Option, 4.5 in (11.43 cm) Width (across DIN rail), 5 in (12.7 cm) Length (along DIN rail) and 4.25 in (10.795 cm) Height (out from DIN rail)  --Automatic on-load voltage regulation for single transformers --Automatic on-load voltage regulation for 4 to 8 transformers in parallel operation, based on the minimum loop current principle or the master-slave follower pinciple  --Control of up to 30 switchgears --Interlocking modules for different wiring methods, ready to use --Various reservation processing functions --Synchronization, simultaneous detection and voltage detection --Dual-position universal switch --32-position selector switch

HCU3700/3703E
TRICONEX HCU3700/3703E Isolated Analog Input

Analog Input Modules Analog Input (AI) Modules includes three independent input channels. Each input channel receives variable voltage signals from each point, converts them to digital values, and transmits the values to the three Main Processor modules on demand. In TMR mode, one value is then selected using a midvalue selection algorithm to ensure correct data for every scan. Sensing of each input point is performed in a manner that prevents a single failure on one channel. Analog Input Modules require a separate external termination panel (ETP) with a cable interface to the Tricon backplane. Each module is mechanically keyed for proper installation in a Tricon chassis. affecting another channel. Each Analog Input Module sustains complete, ongoing diagnostics for each channel. Failure of any diagnostic on any channel activates the Fault indicator for the module, which in turn activates the chassis alarm signal. The module’s Fault indicator merely reports a channelfault, not a module failure—the module can operate properly with as many as two faulty channels.

MP-381-0-0-2
Invensys MP-381-0-0-2 input module

Invensys MP-381-0-0-2 input module Check Prices & Stock Instantly

GCM-86120
Invensys GCM-86120 input module

Invensys GCM-86120 input module Check Prices & Stock Instantly

GCM-ECH-001
Invensys GCM-ECH-001 input module

Invensys GCM-ECH-001 input module Check Prices & Stock Instantly

MP-471-600-0-2
Invensys MP-471-600-0-2 basic module

Invensys MP-471-600-0-2 basic module Ships Today

IDP10-T22A11F-M1L13W
Invensys IDP10-T22A11F-M1L13W basic module

Invensys IDP10-T22A11F-M1L13W basic module Ships Today

MZ2a-106-0-1-1
Invensys MZ2a-106-0-1-1 basic module

Invensys MZ2a-106-0-1-1 basic module Ships Today

© Copyright: 2024 Kerien Automation Co., Ltd. All Rights Reserved.

IPv6 network supported

IPv6 network supported

top

Leave A Message

Leave A Message

    If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

  • #
  • #
  • #