ABB PSE370-600-70 soft starter one year warranty
Item NO.:
PSE370-600-70Payment:
T/TShipping Port:
Xiamen ChinaLead Time:
IN STOCKOrder(MOQ):
1our website : https://www.kerienplc.com/
Kerien Automation Co., Ltd. is located in the beautiful coastal city-Xiamen, Fujian, China. It is one of the beautiful coastal tourist cities in Southeast China.
We are a supplier of industrial automation parts. We focus on PLC modules and DCS cards, and undertake PLC control cabinets and inverter control cabinets. The brands are as follows:
Invensys Foxboro,Invensys Triconex,Rockwell Allen-Bradley Relianc,Schneider Modicon,ABB,Siemens,GE FANUC,Yaskawa,Bosch Rexroth,Westinghouse,Woodward,Ovatin...etc.
The grounding screw is insulated due to the rubber between the cabinet body and the base, and the shielding busbar is insulated from the base. The field control station shall be grounded according to the regulations. That is, they are respectively connected to the grounding busbar of the field control station. The power ground of I/O cabinet and UPS are connected to the same ground to ensure equipotential. 2. Each hardware equipment operator station, engineer station, network switch, server host, system display, etc. shall be grounded by shell or directly connected to the electrical grounding grid. 3. The 40 terminal of the analog module of the I/O module, namely the negative terminal of DC 24V, is connected to the logic grounding bus, the logic grounding bus is connected to the shielding ground, and then connected to the general grounding bus. 4. Shielding ground The protective ground of the field control station shall be connected from the grounding screw under the cabinet to the grounding branch line, and the shielding ground of the field control station shall be connected from the grounding bus bar to the public connection board. 5. Grounding resistance test The resistance of the grounding system shall be tested to ensure that the grounding can meet the requirements of the control system manufacturer. 1 The shell, instrument panel, cabinet, box, box, cable trough, protective tube, support, base and other normal and uncharged metal parts of the electrical instrument that may have dangerous voltage due to insulation damage shall be grounded for protection. For local instruments and switches with power supply voltage not higher than 36V, protective grounding is not required when there are no special requirements in the design documents.
CI840kit 3BSE031694R4000
TU846 3BSE022460R1
TU847 3BSE022462R1
TK212A 3BSC630197R1
FS801K01 3BSE038407R1
AI810 3BSE008516R1
AI815 3BSE052604R1
AI820 3BSE008544R1
AI825 3BSE036456R1
AI830A 3BSE040662R1
AI835A 3BSE051306R1
AI843 3BSE028925R1
AI845 3BSE023675R1
AI890 3BSC690071R1
AI893 3BSC690141R1
AI895 3BSC690086R1
AO810V2 3BSE038415R1
AO815 3BSE052605R1
AO820 3BSE008546R1
AO845A 3BSE045584R1
AO890 3BSC690072R1
AO895 3BSC690087R1
DI810 3BSE008508R1
DI811 3BSE008552R1
DI814 3BUR001454R1
DI820 3BSE008512R1
DI821 3BSE008550R2
DI825 3BSE036373R1
DI830 3BSE013210R1
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!
Categories
New Products
Emerson inverter MFC075B0A1 MFC075B0M2 MFC075B0M16 Read More
SEW servo drive frequency converter MDX61B0150-503-4-00/0T Read More
AB 1768-PA3 industrial control PLC input power supply Read More
2094-BC07-M05-M 2094-BC07-M05-S American AB Kinetix6200 servo driver 2094BC07M05S 2094BC07M05S Read More
MFC075BOM2 MFC075B0T1 MFC075BOM16 Emerson inverter board Read More
SPMA1422 Unidrive SPM Series Drive Inverter Module Read More
© Copyright: 2024 Kerien Automation Co., Ltd. All Rights Reserved.
IPv6 network supported