ABB ACS880-01-105A-3+K473 transducer Ship to Worldwide
Item NO.:
ACS880-01-105A-3+K47Payment:
T/TShipping Port:
Xiamen ChinaLead Time:
IN STOCKOrder(MOQ):
1our website : https://www.kerienplc.com/
Kerien Automation Co., Ltd. is located in the beautiful coastal city-Xiamen, Fujian, China. It is one of the beautiful coastal tourist cities in Southeast China.
We are a supplier of industrial automation parts. We focus on PLC modules and DCS cards, and undertake PLC control cabinets and inverter control cabinets. The brands are as follows:
Invensys Foxboro,Invensys Triconex,Rockwell Allen-Bradley Relianc,Schneider Modicon,ABB,Siemens,GE FANUC,Yaskawa,Bosch Rexroth,Westinghouse,Woodward,Ovatin...etc.
The grounding screw is insulated due to the rubber between the cabinet body and the base, and the shielding busbar is insulated from the base. The field control station shall be grounded according to the regulations. That is, they are respectively connected to the grounding busbar of the field control station. The power ground of I/O cabinet and UPS are connected to the same ground to ensure equipotential. 2. Each hardware equipment operator station, engineer station, network switch, server host, system display, etc. shall be grounded by shell or directly connected to the electrical grounding grid. 3. The 40 terminal of the analog module of the I/O module, namely the negative terminal of DC 24V, is connected to the logic grounding bus, the logic grounding bus is connected to the shielding ground, and then connected to the general grounding bus. 4. Shielding ground The protective ground of the field control station shall be connected from the grounding screw under the cabinet to the grounding branch line, and the shielding ground of the field control station shall be connected from the grounding bus bar to the public connection board. 5. Grounding resistance test The resistance of the grounding system shall be tested to ensure that the grounding can meet the requirements of the control system manufacturer. 1 The shell, instrument panel, cabinet, box, box, cable trough, protective tube, support, base and other normal and uncharged metal parts of the electrical instrument that may have dangerous voltage due to insulation damage shall be grounded for protection. For local instruments and switches with power supply voltage not higher than 36V, protective grounding is not required when there are no special requirements in the design documents.
DI814 3BUR001454R1
DI820 3BSE008512R1
DI821 3BSE008550R2
DI825 3BSE036373R1
DI830 3BSE013210R1
DI831 3BSE013212R1
DI840 3BSE020836R1
DI885 3BSE013088R1
DI890 3BSC690073R1
DO810 3BSE008510R1
DO814 3BUR001455R1
DO815 3BSE013258R1
DO820 3BSE008514R1
DO821 3BSE013250R1
DO840 3BSE020838R1
DO890 3BSC690074R1
DP820 3BSE013228R1
DP840 3BSE028926R1
TU805K01 3BSE035990R1
TU810V1 3BSE013230R1
TU811V1 3BSE013231R1
TU812V1 3BSE013232R1
TU813 3BSE036714R1
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!
Categories
New Products
Emerson inverter MFC075B0A1 MFC075B0M2 MFC075B0M16 Read More
SEW servo drive frequency converter MDX61B0150-503-4-00/0T Read More
AB 1768-PA3 industrial control PLC input power supply Read More
2094-BC07-M05-M 2094-BC07-M05-S American AB Kinetix6200 servo driver 2094BC07M05S 2094BC07M05S Read More
MFC075BOM2 MFC075B0T1 MFC075BOM16 Emerson inverter board Read More
SPMA1422 Unidrive SPM Series Drive Inverter Module Read More
© Copyright: 2024 Kerien Automation Co., Ltd. All Rights Reserved.
IPv6 network supported