GE IS420ESWBH2A mimic control panel New in stock
Item NO.:
IS420ESWBH2APayment:
T/TShipping Port:
Xiamen ChinaLead Time:
IN STOCKOrder(MOQ):
1our website : https://www.kerienplc.com/
Kerien Automation Co., Ltd. is located in the beautiful coastal city-Xiamen, Fujian, China. It is one of the beautiful coastal tourist cities in Southeast China.
We are a supplier of industrial automation parts. We focus on PLC modules and DCS cards, and undertake PLC control cabinets and inverter control cabinets. The brands are as follows:
Invensys Foxboro,Invensys Triconex,Rockwell Allen-Bradley Relianc,Schneider Modicon,ABB,Siemens,GE FANUC,Yaskawa,Bosch Rexroth,Westinghouse,Woodward,Ovatin...etc.
Problems to be noticed in digital signal connection
The input signals of the frequency converter include the digital input signals (switch type command signals) for operation of running/stop, forward/reverse, inching and other operating states. These signals are often from the digital output signals of PLC. PLC usually uses its internal relay contact (relay output type PLC) or components with switching characteristics (transistor output type PLC) to connect with the frequency converter to get the operation state command, as shown in Figure 1 and Figure 2. Attention shall be paid to the following when connecting digital signals:
(1) When the relay output type PLC is used to connect with the frequency converter, it should be noted that poor contact often leads to incorrect operation of the frequency converter, so the connection should be reliable in the actual wiring.
(2) When the transistor output type PLC is used to connect with the frequency converter, it should be noted that the voltage and current of the transistor itself are within their limits to ensure the reliability of the system.
(3) When designing the input signal circuit of the frequency converter, inductive loads such as relays should be avoided as much as possible. The surge current generated by the opening and closing of relays may cause the wrong operation of the frequency converter.
(4) When the switch signal outputted by PLC enters the frequency converter, sometimes there will be crosstalk between the external power supply and the control power supply of the frequency converter. Pay attention to separate grounding of PLC and the frequency converter to avoid using a common grounding wire.
GE Fanuc IC600-CB5150 Control Module ! WOW !
GE FANUC IC3600LSFD1 NSPP IC3600LSFD1
GE FANUC IC3600-TLFC1 NSPP IC3600TLFC1
GE Fanuc A20B-2900-0480/A20B29000480/A20B-2902-0531/02A
GE FANUC IC693CMM301 NSFP IC693CMM301
GE FANUC IC3600VDAC1 USPP IC3600VDAC1
GE FANUC IC3622GTCC6 USPP IC3622GTCC6
GE FANUC IC3600VANB1 USPP IC3600VANB1
GE FANUC IC693ALG222 NSFP IC693ALG222
GE FANUC IC3600AOAA1A NSPP IC3600AOAA1A
GE FANUC IC655MDL527 NSFP IC655MDL527
GE FANUC IC660-ELB906M *USED*
GE FANUC IC660-ELB906S *USED*
GE FANUC IC600CB515Q CONTROL MODULE
GE Fanuc Universal PLC/Controls Simulator *EXCELLENT*
w/ A860-0201-T001 Manual Pulse Generator
GE FANUC IC660BBR101P
GE FANUC IC693ALG223-D IC693ALG223D INPUT ANALOG
GE FANUC A06B-0313-B006#7000 USED SERVO MOTOR A06B0313B006
GE FANUC CPU 364 240K IC693CPU364-CH
without front panel
Previous:
GE IC693CPU363LT CPU moduleNext:
GE IC200UAL005 Driver moduleIf you have questions or suggestions,please leave us a message,we will reply you as soon as we can!
Categories
© Copyright: 2025 Kerien Automation Co., Ltd. All Rights Reserved.
IPv6 network supported